• Variable Pressure Technology and lower pressure options enhance patient comfort
• Proprietary internal and external filter system for an extra layer of safety
• Multiple alarm and safety features that protect the patient
• Variety of dressing options available (foam and gauze)
• Large, easy-to-read, color-coded display screens
• 24 to 48 hour battery run times
• Multi-language capability
• Virtually silent operation
• Cost-effective outcomes
The DeRoyal Pro-III Negative Pressure Wound Therapy System is indicated for patients who would benefit from a suction device, particularly as the device may promote wound healing.
The DeRoyal Pro-III Negative Pressure Wound Therapy System is contraindicated in the presence of: necrotic tissue; unexplored or non-enteric fistulas; untreated osteomyelitis; wounds containing malignant tissue; exposed arteries, veins or organs.
Precautions should be taken in the presence of: anticoagulation or active bleeding; difficult wound hemostasis; close proximity of blood vessels, organs, muscle and fascia requiring adequate protection; irradiated vessels and tissue; bony fragments; untreated malnutrition; non-compliance.
Accommodates large wounds | ● |
Accommodates small wounds | ● |
Adjustable PSI | ● |
Antimicrobial interface available | ● |
Battery-operated | ● |
Disposable | |
Foam interface | ● |
Gauze interface | |
Instillation function | |
Intermittent-pressure setting | ● |
Irrigation function | ● |
Portable (under 1lb) | |
Single-use – 10 days | |
Single-use – 15 days | |
Single-use – 30 days | |
Single-use – 7 days | |
Touchscreen | |
Usable on closed wounds | ● |
Usable on open wounds | ● |
Variable pressure setting | ● |
Educational Material Available | ● |
Free Samples/Trials Available | ● |
Published Clinical Article Available | ● |
Acute Wounds
Chronic Wounds
Dehisced Wounds
Moderate/Highly Exudating Wounds
Superficial Wounds
Surgical Wounds
Venous Ulcers
290mmx259mm(+100 for the canister)x130mm, 2.2kg.
Airflow rate of pump: 8L per minute
Negative pressure: Max - 200mmHg (Conversion factor: 1kPa - 7.5mmHg)
Collection canister: Disposable canister systems
Suction tubing: Various drainage systems, depending on supplier and specific application. Type and kind of use are determined by the medical staff.
Nominal voltage of power supply adapter: 100-240V primary, 12VDC secondary
Power requirements: 100-240V, 50/60Hz, 45W
Maximum load current: 1.25A
Mains frequency of power supply adapter: 50/60Hz
Nominal voltage of electronic circuit board: 12V
Power consumption: 15W (charging operation)/10W(charging only)
Current consumption: 1.25A
Rechargeable battery: 7.4V, 4.4Ah - lithium-ion battery
Charging time of empty battery: 6-7 hours (half empty battery: 3-3.5 hours)
Operating time: AC operation: continuous operation; DC operation: approx. 24-48 hours depending on use
Degree of protection according to IEC 601-1: Type BF
Risk class according to 93/42/EEC, IX: Ita
Sound emission: 35dB (A)
Protection class according to IEC 601-1: II
DeRoyal is a U.S. based international manufacturer producing surgical supply delivery programs, surgical accessories, orthopedic supports, critical care products, negative pressure wound therapy and wound care products.