AVA Cure is an advanced pressure redistribution system featuring intelligent pressure sensing, a user-friendly interface, and anti-bottoming technology. By combining effective pressure redistribution with micro low-air-loss, it provides a superior solution for clinical environments.
• Intelligent pressure sensing technology (IPS)
• Max inflation
• Upright mode
• Static mode
• Dynamic mode
• Memory recall
• Call for services alarm
• Power failure alarm
• Low/high pressure alarm
• User-friendly operating interface
• Multiple cycle time
The therapeutic support system is indicated for the prevention and/or management of all categories of pressure ulcer. The use of this system allows combined with the regular repositioning, monitoring, and nursing of the patient.
Certain patient conditions are not suitable for using this type of device such as fracture of unstable vertebrae and illness of unstable vertebrae (include spinal cord injury, cervical traction).
1. Always consult a physician or health professional before using the AVA Cure system. Any and all applications outside of the conditions specified above are regarded as unapproved. The user and the operator respectively are exclusively liable for any damage resulting from the unapproved use.
2. If existing wounds do not improve or the patient’s condition changes the overall therapy regimen should be reviewed by the consult physicians.
A. Strangulation by extra-long cables and hoses: To avoid entanglement, keep children clear of hoses.
B. Choking caused by small parts being inhaled or swallowed: Identify any loose or detached small parts that may be an issue
C. Potential allergic reactions to accessible materials used in the equipment: Identify any rubber or latex that could be an issue.
D. Contact Injuries: Check for any skin irritation due to prolonged contact with the equipment.
E. Protection against strangulation or asphyxiation: Means shall be provided to control the risk of strangulation and asphyxiation of the patient and other to an acceptable level by routing wires or tubing, and using retention devices.
F. To prevent the effects caused by pets, pests or children.
G. To avoid the effects of degraded sensor or loosened electrodes, that can degrade performance or cause other problems.
Power Unit Model: REF: SR397
Power Input: 100-120Vac 60Hz 0.2A
Power Consumption: Max. 15W
Weight:
Power Unit: 5.5kg (12lbs)
Mattress Set: 4.5kg (10lbs), 5kg (11lbs)
Dimension:
Power Unit (W x H x D): 33.9 x 26.5 x 13 cm
Mattress Set: (W x L x H):
36” x 80” x 8” (90 x 200 x 20cm)
42” x 80” x 8” (107 x 200 x 20cm)
36” x 84” x 8” (90 x 210 x 20cm)
42” x 84” x 8” (107 x 210 x 20cm)
Operating Conditions:
Temperature: 5°C to 40°C (41°F to 104°F)
Humidity: 15% to 90%
Transportation & Storage Condition:
Temperature: -25°C to 70°C (-13°F to 158°F)
Humidity: 0% to 90%
Product Compliance:
ANSI/AAMI ES60601-1
IEC/EN 60601-1
IEC/EN 60601-1-2
IEC/EN 60601-1-8
Weight Capacity: 180kg (400lbs)